Specialty & Environment-Rated Motors

Some applications don't fail on torque or speed. They fail because the motor wasn't built for where it's installed. Specialty and environment-rated motors are servo motors qualified against a specific operating hazard: washdown and sanitation cycles, explosive atmospheres, or downhole heat and pressure. Electromate supplies three categories, each built around a different hazard type.


What Makes a Motor "Environment-Rated"?

A standard servo motor is rated for typical indoor industrial conditions. An environment-rated motor carries certification against one defined hazard: ingress protection for washdown and contamination, explosion-proof classification for flammable gas, vapor, or dust, or extreme-condition ratings for heat, pressure, and shock. That certification determines where the motor can legally and safely be installed. It's a separate spec from torque, speed, or frame size, and it has to be checked independently.


Compare the Three Categories

Category Primary Hazard Certification / Rating Typical Environments
Washdown & Food-Grade Motors Water, cleaning chemicals, contamination IP67 to IP69K; food-safe lubricants and materials for incidental contact Food & beverage, dairy, pharmaceutical
Hazardous Location & Explosion-Proof Motors Flammable gas, vapor, combustible dust Class I Div 1/2, Zone 2/22, ATEX, IECEx, UL/CSA Oil & gas, chemical processing, mining, grain and flour milling
Downhole & MWD Motors Extreme heat, pressure, shock, and vibration Rated past 200°C; up to 1,700 bar (25,000 psi); optional ATEX Oil & gas drilling: MWD, LWD, RSS, downhole valve actuation

Downhole & MWD Motors

maxon Heavy Duty (HD) brushless servo motors are built for conditions past what standard industrial motors are rated for: sustained operation above 200°C, pressure up to 1,700 bar (25,000 psi), vibration to 25 grms, and shock loads to 1,000 G in select systems. Housings are hermetically sealed stainless steel, with optional ATEX certification and redundant winding for mission-critical reliability. These motors run Measurement While Drilling (MWD), Logging While Drilling (LWD), Rotary Steerable Systems (RSS), and downhole valve actuation.


Food-Grade & Washdown Motors

Kollmorgen AKM Washdown and AKM Food Grade motors, along with the stainless steel W and HKM series, carry IP67 to IP69K sealing with a protective 2-K coating and stainless steel hardware on critical interfaces. Food-grade versions add compliant lubricants and materials rated for incidental food contact under FDA requirements. Washdown resistance and food-grade suitability are two separate qualifications. Some applications, like wet food-processing lines, need both at once.


Hazardous Location & Explosion-Proof Motors

Certification here follows two systems: Class/Division in North America, Zone under ATEX/IECEx internationally. Which one applies depends on the specific gas, vapor, or dust present and how often it's expected to occur. Kollmorgen's AKME series covers Zone 2 and Zone 22 under ATEX and IECEx. The Goldline EB and EBH series cover Class I, Division 1, Groups C & D under UL and CSA, including high-voltage configurations. NEMA 42 and 66 explosion-proof synchronous motors deliver up to 1,500 oz-in (1,059 N-cm) for Class I, Division 1, Group D locations.


Specialty & Environment-Rated Motor Products:

View as List Grid

Items 1-15 of 174

Set Descending Direction
AKMA Series by Kollmorgen

AKMA Series

Up to 8000 rpm speed, 10 Nm torque, IP65 protection

Request Quote
View Details
AKME Hazardous Location Servo Motors by Kollmorgen

AKME Hazardous Location Servo Motors

Designed for closed-loop servo control in applications involving flammable gases, vapors, or combustible dusts, while maintaining mechanical and control compatibility with standard AKM motors.

Request Quote
View Details
AKMH21C (120 VAC) by Kollmorgen

AKMH21C (120 VAC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 5530 RPM Max Speed

Request Quote
View Details
AKMH21C (240 VAC) by Kollmorgen

AKMH21C (240 VAC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH21C (400 VAC) by Kollmorgen

AKMH21C (400 VAC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH21C (480 VAC) by Kollmorgen

AKMH21C (480 VAC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH21E (120 VAC) by Kollmorgen

AKMH21E (120 VAC)

74 mm Diameter, 0.4 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH21E (75 VDC) by Kollmorgen

AKMH21E (75 VDC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 2000 RPM Max Speed

Request Quote
View Details
AKMH21G (75 VDC) by Kollmorgen

AKMH21G (75 VDC)

74 mm Diameter, 0.3 Nm Max Cont. Torque, 4000 RPM Max Speed

Request Quote
View Details
AKMH22C (120 VAC) by Kollmorgen

AKMH22C (120 VAC)

74 mm Diameter, 0.6 Nm Max Cont. Torque, 2790 RPM Max Speed

Request Quote
View Details
AKMH22C (240 VAC) by Kollmorgen

AKMH22C (240 VAC)

74 mm Diameter, 0.6 Nm Max Cont. Torque, 5620 RPM Max Speed

Request Quote
View Details
AKMH22C (400 VAC) by Kollmorgen

AKMH22C (400 VAC)

74 mm Diameter, 0.6 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH22C (480 VAC) by Kollmorgen

AKMH22C (480 VAC)

74 mm Diameter, 0.6 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
AKMH22E (120 VAC) by Kollmorgen

AKMH22E (120 VAC)

74 mm Diameter, 0.7 Nm Max Cont. Torque, 5370 RPM Max Speed

Request Quote
View Details
AKMH22E (240 VAC) by Kollmorgen

AKMH22E (240 VAC)

74 mm Diameter, 0.7 Nm Max Cont. Torque, 8000 RPM Max Speed

Request Quote
View Details
Page
per page

Choosing the Right Category

If the hazard is water, cleaning chemicals, or contamination control: washdown & food-grade.

If the hazard is an explosive atmosphere from gas, vapor, or dust: hazardous location & explosion-proof.

If the hazard is downhole heat, pressure, or shock: downhole & MWD.

If an application spans more than one hazard, such as a hazardous-area food plant, confirm both certifications are available on the same platform before specifying.

When specifying a motor for regulated environments, confirm:

  • Area classification (Class/Division or Zone)
  • Required IP rating
  • Surface material and sanitation requirements
  • Voltage and torque requirements
  • Drive compatibility

Hazardous rating, washdown rating, and hygienic design address separate compliance frameworks. Selection must match the installation environment.